Wellbeing of Alcohol-preferring Rats Euthanized with Carbon Dioxide at Very Low and Low Volume Displacement Rates

dc.contributor.authorHickman, Debra L.
dc.contributor.departmentLaboratory Animal Resource Center, IU School of Medicineen_US
dc.date.accessioned2019-09-09T16:23:19Z
dc.date.available2019-09-09T16:23:19Z
dc.date.issued2019-01-01
dc.description.abstractThe 2013 AVMA Guidelines on Euthanasia recommend the use of very-low or low flow rates of 100% carbon dioxide to euthanize small rodents. Although inhalation of high concentrations of carbon dioxide are generally recognized as painful in humans, whether the use of these low-flow methods of euthanasia increase potential distress for rats is unclear. This study compared physiologic and behavioral markers of animal wellbeing for rats euthanized by using 10% volume displacement per minute (VD/min), 30% VD/min, and 70% VD/min of 100% carbon dioxide. Rats were recorded during euthanasia for subsequent behavioral scoring, and blood samples were taken after euthanasia for assessment of blood glucose and serum corticosterone levels. In this study, rats euthanized with 10% or 30% VD/min of 100% carbon dioxide demonstrated increases in various behaviors, such as rearing and standing, concurrent with increases in serum corticosterone. Rats euthanized with 70% VD/min of 100% carbon dioxide did not exhibit these changes. The results suggest that a euthanasia method of 70% VD/min of 100% carbon dioxide may minimize potential pain and distress and thus be more humane for rats, as compared with very-low- and low-flow methods of carbon dioxide euthanasia.en_US
dc.identifier.citationHickman D. L. (2019). Wellbeing of Alcohol-preferring Rats Euthanized with Carbon Dioxide at Very Low and Low Volume Displacement Rates. Journal of the American Association for Laboratory Animal Science : JAALAS, 58(1), 78–82. doi:10.30802/AALAS-JAALAS-18-000004en_US
dc.identifier.urihttps://hdl.handle.net/1805/20875
dc.language.isoen_USen_US
dc.publisherAmerican Association for Laboratory Animal Scienceen_US
dc.relation.isversionof10.30802/AALAS-JAALAS-18-000004en_US
dc.relation.journalJournal of the American Association for Laboratory Animal Science: JAALASen_US
dc.sourcePMCen_US
dc.subjectEuthanasiaen_US
dc.subjectCarbon dioxideen_US
dc.subjectRatsen_US
dc.subjectAnimal wellbeingen_US
dc.subjectBlood glucoseen_US
dc.subjectSerum corticosteroneen_US
dc.titleWellbeing of Alcohol-preferring Rats Euthanized with Carbon Dioxide at Very Low and Low Volume Displacement Ratesen_US
dc.typeArticleen_US
ul.alternative.fulltexthttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6351044/
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
jaalas201900078.pdf
Size:
128.77 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: