Microtensile Bond Strength and Microleakage of HEMA-Free One-Step Self-Etch Adhesive

Date
2013-04-05
Language
American English
Embargo Lift Date
Department
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Office of the Vice Chancellor for Research
Abstract

This study evaluated the microtensile dentin bond strength (μ-TBS) and microleakage of a one-step HEMA-free self-etch adhesive (G-aenial Bond-GB) compared to a 2-step self-etch (Clearfil SE-SE) and a 3-step etch and rinse (OptiBond FL-OB) adhesive with and without pre-etching with phosphoric acid. Human molars were divided randomly into 5 groups (n=15), GB and SE (without pre-etching), GB+ and SE+ (with pre-etching), and OB. Eight beams were obtained from each tooth and half of the beams were subjected to μ-TBS testing after 2d. The remaining beams were thermocycled (2,500 cycles), aged for 40d and subjected to μ-TBS testing using a universal testing machine. Failures were analyzed using light microscopy and SEM. Similar groups were used for the microleakage test (n=11). Class V cavities were prepared on the buccal and lingual surfaces of each molar. Teeth were thermocycled (2,500 cycles), aged for 40d, soaked in 1% methylene blue dye for 24h, and sectioned longitudinally from the facial to lingual surface. The dye penetration was scored using light microscopy and an ordinal scale from 0-3. Data was analyzed using Weibull, GEE, and Wilcoxon Rank Sum tests (α=0.05). Phosphoric acid pre-etching significantly increased dentin bond strength. After 40d, the mean bond strength ranged from 28.6-45.7 MPa with a statistical significance of GB, SE<GB+, SE+ & OB. The Weibull Characteristic Strength ranged from 31.5-51.0 MPa and the Weibull Modulus ranged from 2.3-4.1. Cohesive failure ranged from 16%-57% with a statistical significance of GB<SE+ & OB, but GB+ & SE<OB. Phosphoric acid preetching had no significant effect on microleakage. However, significant differences were found between coronal and gingival surfaces for all groups except GB. Pre-etching with phosphoric acid significantly increased dentin bond strength of GB and SE and had no significant effect on microleakage. Materials supplied by GC America and Ultradent.

Description
poster abstract
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
AlZain, Afnan, George Eckert, and Jeffrey Platt. (2013, April 5). Microtensile Bond Strength and Microleakage of HEMA-Free One-Step Self-Etch Adhesive. Poster session presented at IUPUI Research Day 2013, Indianapolis, Indiana.
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Rights
Source
Alternative Title
Type
Poster
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Full Text Available at
This item is under embargo {{howLong}}