A task and performance analysis of endoscopic submucosal dissection (ESD) surgery

Date
2019-02
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Springer Verlag
Abstract

BACKGROUND:

ESD is an endoscopic technique for en bloc resection of gastrointestinal lesions. ESD is a widely-used in Japan and throughout Asia, but not as prevalent in Europe or the US. The procedure is technically challenging and has higher adverse events (bleeding, perforation) compared to endoscopic mucosal resection. Inadequate training platforms and lack of established training curricula have restricted its wide acceptance in the US. Thus, we aim to develop a Virtual Endoluminal Surgery Simulator (VESS) for objective ESD training and assessment. In this work, we performed task and performance analysis of ESD surgeries. METHODS:

We performed a detailed colorectal ESD task analysis and identified the critical ESD steps for lesion identification, marking, injection, circumferential cutting, dissection, intraprocedural complication management, and post-procedure examination. We constructed a hierarchical task tree that elaborates the order of tasks in these steps. Furthermore, we developed quantitative ESD performance metrics. We measured task times and scores of 16 ESD surgeries performed by four different endoscopic surgeons. RESULTS:

The average time of the marking, injection, and circumferential cutting phases are 203.4 (σ: 205.46), 83.5 (σ: 49.92), 908.4 s. (σ: 584.53), respectively. Cutting the submucosal layer takes most of the time of overall ESD procedure time with an average of 1394.7 s (σ: 908.43). We also performed correlation analysis (Pearson's test) among the performance scores of the tasks. There is a moderate positive correlation (R = 0.528, p = 0.0355) between marking scores and total scores, a strong positive correlation (R = 0.7879, p = 0.0003) between circumferential cutting and submucosal dissection and total scores. Similarly, we noted a strong positive correlation (R = 0.7095, p = 0.0021) between circumferential cutting and submucosal dissection and marking scores. CONCLUSIONS:

We elaborated ESD tasks and developed quantitative performance metrics used in analysis of actual surgery performance. These ESD metrics will be used in future validation studies of our VESS simulator.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Cetinsaya, B., Gromski, M. A., Lee, S., Xia, Z., Demirel, D., Halic, T., Bayrak, C., Jackson, C., De, S., Hegde, S., Cohen, J., Sawhney, M., Stavropoulos, S. N., & Jones, D. B. (2019). A task and performance analysis of endoscopic submucosal dissection (ESD) surgery. Surgical endoscopy, 33(2), 592–606. https://doi.org/10.1007/s00464-018-6379-6
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Surgical Endoscopy
Rights
Publisher Policy
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}