Automated and manual hippocampal segmentation techniques: Comparison of results, reproducibility and clinical applicability

Date
2019
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

BACKGROUND:

Imaging techniques used to measure hippocampal atrophy are key to understanding the clinical progression of Alzheimer's disease (AD). Various semi-automated hippocampal segmentation techniques are available and require human expert input to learn how to accurately segment new data. Our goal was to compare 1) the performance of our automated hippocampal segmentation technique relative to manual segmentations, and 2) the performance of our automated technique when provided with a training set from two different raters. We also explored the ability of hippocampal volumes obtained using manual and automated hippocampal segmentations to predict conversion from MCI to AD. METHODS:

We analyzed 161 1.5 T T1-weighted brain magnetic resonance images (MRI) from the ADCS Donepezil/Vitamin E clinical study. All subjects carried a diagnosis of mild cognitive impairment (MCI). Three different segmentation outputs (one produced by manual tracing and two produced by a semi-automated algorithm trained with training sets developed by two raters) were compared using single measure intraclass correlation statistics (smICC). The radial distance method was used to assess each segmentation technique's ability to detect hippocampal atrophy in 3D. We then compared how well each segmentation method detected baseline hippocampal differences between MCI subjects who remained stable (MCInc) and those who converted to AD (MCIc) during the trial. Our statistical maps were corrected for multiple comparisons using permutation-based statistics with a threshold of p < .01. RESULTS:

Our smICC analyses showed significant agreement between the manual and automated hippocampal segmentations from rater 1 [right smICC = 0.78 (95%CI 0.72-0.84); left smICC = 0.79 (95%CI 0.72-0.85)], the manual segmentations from rater 1 versus the automated segmentations from rater 2 [right smICC = 0.78 (95%CI 0.7-0.84); left smICC = 0.78 (95%CI 0.71-0.84)], and the automated segmentations of rater 1 versus rater 2 [right smICC = 0.97 (95%CI 0.96-0.98); left smICC = 0.97 (95%CI 0.96-0.98)]. All three segmentation methods detected significant CA1 and subicular atrophy in MCIc compared to MCInc at baseline (manual: right pcorrected = 0.0112, left pcorrected = 0.0006; automated rater 1: right pcorrected = 0.0318, left pcorrected = 0.0302; automated rater 2: right pcorrected = 0.0029, left pcorrected = 0.0166). CONCLUSIONS:

The hippocampal volumes obtained with a fast semi-automated segmentation method were highly comparable to the ones obtained with the labor-intensive manual segmentation method. The AdaBoost automated hippocampal segmentation technique is highly reliable allowing the efficient analysis of large data sets.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Hurtz, S., Chow, N., Watson, A. E., Somme, J. H., Goukasian, N., Hwang, K. S., … Apostolova, L. G. (2019). Automated and manual hippocampal segmentation techniques: Comparison of results, reproducibility and clinical applicability. NeuroImage. Clinical, 21, 101574. doi:10.1016/j.nicl.2018.10.012
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
NeuroImage: Clinical
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}