Reproducibility of oligonucleotide arrays using small samples

Date
2003-07-30
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
BioMed Central
Abstract

Background Low RNA yields from small tissue samples can limit the use of oligonucleotide microarrays (Affymetrix GeneChips®). Methods using less cRNA for hybridization or amplifying the cRNA have been reported to reduce the number of transcripts detected, but the effect on realistic experiments designed to detect biological differences has not been analyzed. We systematically explore the effects of using different starting amounts of RNA on the ability to detect differential gene expression.

Results The standard Affymetrix protocol can be used starting with only 2 micrograms of total RNA, with results equivalent to the recommended 10 micrograms. Biological variability is much greater than the technical variability introduced by this change. A simple amplification protocol described here can be used for samples as small as 0.1 micrograms of total RNA. This amplification protocol allows detection of a substantial fraction of the significant differences found using the standard protocol, despite an increase in variability and the 5' truncation of the transcripts, which prevents detection of a subset of genes.

Conclusions Biological differences in a typical experiment are much greater than differences resulting from technical manipulations in labeling and hybridization. The standard protocol works well with 2 micrograms of RNA, and with minor modifications could allow the use of samples as small as 1 micrograms. For smaller amounts of starting material, down to 0.1 micrograms RNA, differential gene expression can still be detected using the single cycle amplification protocol. Comparisons of groups of four arrays detect many more significant differences than comparisons of three arrays.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
McClintick, J.N., Jerome, R.E., Nicholson, C.R. et al. Reproducibility of oligonucleotide arrays using small samples. BMC Genomics 4, 4 (2003). https://doi.org/10.1186/1471-2164-4-4
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
BMC Genomics
Source
Publisher
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}