Abstract 68: The False Positive Rate Of Transcutaneous Tissue Oximetry Alarms In Microvascular Breast Reconstruction Rises After 24 Hours

Date
2020-05-13
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Wolters Kluwer
Abstract

Purpose: Transcutaneous tissue oximetry is widely used as an adjunct for postoperative monitoring after microvascular breast reconstruction and has been shown to improve flap salvage rates. Despite a high sensitivity at detection of postoperative vascular issues, alarms from probe malfunctions/ and or positioning can generate unnecessary nursing calls, concerns, and evaluations. The purpose of this study is to analyze the false positive rate of transcutaneous tissue oximetry monitoring over the postoperative period and assess changes in its utility over time.

Methods: Consecutive patients undergoing microvascular breast reconstruction out our institution were assessed between 2017-2019. Inclusion criteria included use of transcutaneous tissue oximetry for monitoring. Variables of interest were transcutaneous tissue oximetry alarms that triggered nursing calls, flap loss, re-exploration, and salvage rates.

Results: The study included 175 patients (286 flaps). The flap loss rate was 1.0% (3/175). A total of twelve patients (6.8%) required re-exploration, with a 67.0% flap salvage rate. Nine of these patients required exploration within 24 hours. The 3 takebacks after 24 hours were not for vascular compromise but were for abdominal wall hematoma, increasingly sanguineous drain output, and exam concerning for hematoma. Within the 24-hour postoperative period, 43 tissue oximetry alarms triggered nursing calls; 7 alarms (16.2%) were confirmed to be for flap issues secondary to vascular compromise. After 24 hours, 44 alarms were triggered, none of which were associated with flap compromise. The false positive rate of the alarm within 24 hours was 83.7% (36/43) compared to 100% (44/44) after 24 hours (p= 0.01).

Conclusions: Transcutaneous tissue oximetry is a helpful adjunct to the clinical exam in the postoperative monitoring of flaps in microsurgical breast reconstruction. The false positive rate significantly rises after 24 hours. The benefit may not outweigh the concerns, labor, and effort that results from alarms after postoperative day 1. We recommend considering discontinuing transcutaneous tissue oximetry monitoring after 24 hours.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Tran, P. C., DeBrock, W., Lester, M. E., Hartman, B. C., Socas, J., & Hassanein, A. H. (2020). Abstract 68: The False Positive Rate Of Transcutaneous Tissue Oximetry Alarms In Microvascular Breast Reconstruction Rises After 24 Hours. Plastic and Reconstructive Surgery – Global Open, 8(4S), 44. https://doi.org/10.1097/01.GOX.0000667332.08635.3e
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Plastic and Reconstructive Surgery – Global Open
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Full Text Available at
This item is under embargo {{howLong}}